PT-104 USB PT100 DATA LOGGER ACCURACY AND RESOLUTION
Although accurate temperature sensors are widely available, it has been difficult to find a measuring device that can take advantage of them without introducing excessive errors. The PT-104 USB, however, is inherently accurate due to its novel design. Rather than relying on voltage references (which tend to be temperaturesensitive) it uses reference resistors which are extremely stable (low temperature coefficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly recalibration is recommended). To achieve the 0.001°C resolution, a highly advanced ADC is used that can resolve to better than 1 part in 16 million.
TEMPERATURE
The PT-104 USB measures temperature using platinum resistance thermometers (PRTs). Both common industry standards (PT100 and PT1000) are supported. The unit is compatible with 2, 3 and 4 wire sensors (4 wire PT100 sensors are recommended for accurate measurements). A wide range of PT100 sensors are available for use with the PT-104.
- MEASURES TEMPERATURE, RESISTANCE AND VOLTAGE
- HIGH RESOLUTION AND ACCURACY
- CONNECT VIA USB OR ETHERNET PORT |  |
|
 |
|
 |
 |
|
ADC-11The ADC-11 has been discontinued; however, due to its popularity, the PicoLog 1000 Series logger includes a USB ADC-11 compatibility mode which enables it to act as a direct replacement for the USB ADC-11.
|
|
 |
|
 |
TC-08 - 8 CHANNEL THERMOCOUPLE DATA LOGGER - MEASURES FROM -270°C TO +1820°C - AUTOMATIC COLD CONJUNCTION COMPENSATION - HIGH RESOLUTION AND ACCURACY
Channels 8 Resolution 20 bits Input range ±70 mV Conversion time 100 ms Temperature accuracy Sum of ±0.2 % of reading and ±0.5°C Voltage accuracy Sum of ±0.2 % of reading and ±10 ìV Thermocouple types supported B, E, J, K, N, R, S, T |  |
|
 |
|
 |
 |
TC-08 TERMINAL BOARD This is an optional terminal board for the TC-08. The screw terminals allow wires to be attached to the data logger without soldering and enable the TC-08 to measure voltages from 0 to +5 V, or 4-20 mA loop current. |  |
|
 |
|
 |
 |
|
 |
 |
Calibration Certificate At Alphatemp we provide a complete calibration service for all instruments and probes regardless of make or model.
These start with our own In-house calibration services to certified standards carried out in our controlled modern laboratory and lead to UKAS Accredited Traceable Certificates, and although we are not a UKAS accredited laboratory we are able to have this work carried out for you by an accredited laboratory, therby reducing the number of vital probe and instrument movements!
Please see our section on Calibration Services for prices...
|  |
|
 |