Alphatemp Technology

BASKET | CHECKOUT | Items:, Value:

Call Us: + 44/0 1376 344679

ACTIVE PROBES


Alphatemp Technology > PICO TECHNOLOGY Pico OscilloscopesOscilloscope Accessories >ACTIVE PROBES
 

ACTIVE DIFFERENTIAL PROBE 700 TO 7000 V, 70 TO 100 MHz

The TA042, TA043 and TA044 are active differential oscilloscope probes. They let you use a conventional earthed oscilloscope to measure signals that are not referenced to ground, including mains voltages. They can also be used to measure and observe the waveforms of three-phase supplies or the gate and control signals of semiconductor circuits. They are ideal for investigating motor speed controls, uninterruptible power supplies, switch mode power supplies and process controllers.

ACTIVE DIFFERENTIAL PROBE 700 TO 7000 V, 70 TO 100 MHz

ACTIVE DIFF PROBE 1400 V, 100 MHz SPECIFICATION

Description: 100 MHz 1400 V differential probe
Attenuation: 100:1, 1000:1
Bandwidth: 100 MHz
Rise Time: 3.5 ns
Differential voltage range: 140 V DC + peak AC: 100 V RMS
70 V + peak AC: 70 V RMS
Common mode range: 1400 V + peak AC: 1000 V RMS
Input impedance: 4 MΩ/7 pF each side to ground
Power requirements: 4 x AA cells (supplied)
Safety rating: CAT III

Ref: KI-TA042ACTIVE DIFF PROBE 1400 V, 100 MHz  
   £330.00 / €396.00 
Qty:    

ACTIVE DIFF PROBE 700 V, 100 MHz SPECIFICATION

Description: 100 MHz 700 V differential probe
Attenuation: 10:1, 100:1
Bandwidth: 100 MHz
Rise Time: 3.5 ns
Differential voltage range: 700 V + peak AC: 500 V RMS
1400 V + peak AC: 1000 V RMS
Common mode range: 700 V + peak AC: 500 V RMS
Input impedance: 4 MŁ/7 pF each side to ground
Power requirements: 4 x AA cells (supplied)
Safety rating: CAT III

Ref: KI-TA043ACTIVE DIFF PROBE 700 V, 100 MHz  
   £450.00 / €540.00 
Qty:    

ACTIVE DIFF PROBE 7000 V, 70 MHz SPECIFICATION

Description: 70 MHz 7000 V differential probe
Attenuation: 100:1, 1000:1
Bandwidth: 70 MHz
Rise Time: 3.5 ns
Differential voltage range: 700 V + peak AC: 500 V RMS
7000 V + peak AC: 5000 V RMS
Common mode range: 7000 V + peak AC:2500 V RMS
Input impedance: 10 MŁ/10 pF each side to ground
Power requirements: 4 x AA cells (supplied)
Safety rating: CAT I

Ref: KI-TA044ACTIVE DIFF PROBE 7000 V, 70 MHz  
   £480.00 / €576.00 
Qty:    
 

ACTIVE DIFFERENTIAL PROBE 60 V, 200 MHz

The TA045 is a CAT I rated differential oscilloscope probe that can measure up to
±20 volts.

ACTIVE DIFFERENTIAL PROBE 60 V, 200 MHz

ACTIVE DIFF PROBE SPECIFICATION

Bandwidth: 200 MHz
Attenuation: 10:1
Common mode: ±60 V
Differential: ±20 V
Input impedance: 500 kŁ / 7 pF
Battery power: Optional (TA047)
Safety rating: CAT I

Ref: KI-TA045ACTIVE DIFF PROBE 60 V, 200 MHz TA045 £600 
   £600.00 / €720.00 
Qty:    
 

TETRIS 1000 AND 1500 HIGH-IMPEDANCE ACTIVE PROBES

The TETRIS active probes can contact adjacent square pins in 2.54 mm pitch simultaneously. The probe’s housing is T-shaped so that many probes can be positioned next to each other in a continuous chain. This allows a number of measurements to be taken at the same time.

TETRIS 1000 AND 1500 HIGH-IMPEDANCE ACTIVE PROBES

TETRIS PROBE SPECIFICATION

Attenuation 10:1
Input impedance 1 MÙ
Input capacitance 0.9 pF
Working voltage 20 V
Cable length 1.3 m

TETRIS 1000: Bandwidth 1 GHz

TETRIS 1500: Bandwidth 1.5 GHz

Ref: KI-TA112TETRIS 1000 PROBE  
   £445.00 / €534.00 
Qty:    
Ref: KI-TA113TETRIS 1500 PROBE  
   £580.00 / €696.00 
Qty:    
 

ACTIVE DIFFERENTIAL PROBE 1000 V OR 1400 V CAT III

The probe permits a conventional earthed oscilloscope to measure signals that are not referenced to earth, enabling mains voltages to be tested. Ideal for investigation of motor speed
controls, uninterruptible power supplies, switch mode power supplies and process controllers.

ACTIVE DIFFERENTIAL PROBE 1000 V OR 1400 V CAT III

TA041 SPECIFICATION

Attenuation ranges: Bandwidth: Differential voltage range: ±70 V or 70 V RMS
±700 V or 700 V RMS
Common mode voltage range: Input impedance: 4 MŁ / 5.5 pF
Safety rating:

Ref: KI-TA041ACTIVE DIFF PROBE 1000 V, 25 MHz  
   £195.00 / €234.00 
Qty:    
Ref: KI-TA057ACTIVE DIFF PROBE 1400 V, 25 MHz  
   £220.00 / €264.00 
Qty:    
 

ACTIVE DIFFERENTIAL PROBE 15 V, 800 MHz, X1/10, CAT III

The TA046 is a high-bandwidth differential probe. It is ideal for measuring high-speed differential signals.

ACTIVE DIFFERENTIAL PROBE 15 V, 800 MHz, X1/10, CAT III

TA046 SPECIFICATION

Attenuation 10:1
Bandwidth 800 MHz
Common mode ±30 V
Differential ±15 V
Input impedance 100 kÙ / 2 pF

Ref: KI-TA046ACTIVE DIFF PROBE 15 V, 800 MHz  
   £800.00 / €960.00 
Qty:    
 

ACTIVE DIFFERENTIAL PROBE 70 V, 50 MHz, x1/10, CAT I

The TA058 is a CAT I rated differential oscilloscope probe that can measure up to
±70 volts.

ACTIVE DIFFERENTIAL PROBE 70 V, 50 MHz, x1/10, CAT I

TA058 SPECIFICATION

Attenuation 10:1
Bandwidth 50 MHz
Common mode ±700 V
Differential ±70 V
Battery power Optional (TA047)
Input impedance 1.6 MÙ / 7 pF
Safety rating CAT I

Ref: KI-TA058ACTIVE DIFF PROBE 70 V, 50 MHz  
   £245.00 / €294.00 
Qty:    

ACCESSORIES FOR ACTIVE PROBES

The TA047 is an optional 4AA battery pack for the TA045 and TA046 active differential probes. We also offer power supplies should you need to buy a new one. The PS008 is a 9 V power supply for all TA differential probes. The PS009 is a 15 V power supply for the TA046 only.

Ref: KI-TA047BATTERY PACK 4AA FOR TA045/TA046  
   £37.00 / €44.40 
Qty:    
Ref: KI-PS0089 V POWER SUPPLY (NOT TA046)  
   £15.00 / €18.00 
Qty:    
Ref: KI-PS00915 V POWER SUPPLY (TA046 ONLY)  
   £15.00 / €18.00 
Qty:    
 

3D PROBE POSITIONER

This 3D probe positioner is for scope probes and other measuring devices. This allows for hands-free testing and measuring, with accurate and safe positioning. It offers a stepless 3D clamping system. Available with fixed probe holder (MS100) or adjustable clamp (MSU1500).

3D PROBE POSITIONER
Ref: KI-TA115PROBE POSITIONER MSA100  
   £270.00 / €324.00 
Qty:    
Ref: KI-TA116PROBE POSITIONER MSU1500  
   £385.00 / €462.00 
Qty:    

Alphatemp Technology > PICO TECHNOLOGY Pico OscilloscopesOscilloscope Accessories >ACTIVE PROBES
spacer
spacer